0

Logged in as:

Show all filters

Hide all filters

RDOE (H07RN-F) - Spool


NEMIQ
Number of cores:
2-7 .
Material core insulation:
Rubber
Specification core insulation:
Rubber - ethylene propylene rubber (EPR)
Core identification:
Colour
Protective conductor:
Yes, No
Material outer sheath:
Rubber
Specification material outer sheath:
Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-60 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
60 °C
Screen:
No
Armouring/reinforcement:
None
Drain wire:
No
Nominal voltage:
750 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black
Material insulation:
EPDM
Operating temperature:
-25-60 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
55-111 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

H01N2-D FT - Spool


NEMIQ
Number of cores:
1 .
Material core insulation:
Rubber
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-20-80 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
80 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Single insulated
Core colour:
Red, Black
Conductor surface:
Tinned
Min. permitted bending radius, stationary application/permanent installation:
58.2-115.2 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Model:
UL model
Number of branches:
0 N/A
Colour insulation:
Blue, Yellow, Red
Sleeve form:
Short
Suitable for solid cores:
Yes
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
For pull protected connections:
No
Voltage level:
Up to 600 V
Type of connection:
Other
Oil stop/centre bar:
No
Surface protection:
Tinned
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V0
Operating temperature:
-40-75 °C
Material:
Copper
Voltage max:
600V
Halogen free:
No
V0
UL-File No.:
E42024
Yes
Yes
Yes

NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Model:
UL model
Number of branches:
0 N/A
Colour insulation:
Yellow
Sleeve form:
Short
Suitable for solid cores:
Yes
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
For pull protected connections:
No
Voltage level:
Up to 600 V
Type of connection:
Other
Oil stop/centre bar:
No
Surface protection:
Tinned
Material insulation:
Polyamide (PA)
Fire classification:
According to UL94V2
Operating temperature:
-25-105 °C
Material:
Copper
Voltage max:
600V
Halogen free:
Yes
V2
Yes
Yes

Bullet female terminals A-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Model:
Bushing
Max. current (Imax):
10-15 A
Insulation:
Fully isolated
Colour insulation:
Blue, Red
With cam clamp:
No
With tap spreader:
No
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V0
Operating temperature:
-40-75 °C
Material:
Brass
Voltage max:
300V
Halogen free:
No
V0
UL-File No.:
E42024
Yes
Yes
Yes

Bullet male terminals A-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Model:
Plug
Max. current (Imax):
10-15 A
Insulation:
Partially isolated
Colour insulation:
Blue, Red
With cam clamp:
No
With tap spreader:
No
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V0
Operating temperature:
-40-75 °C
Material:
Brass
Voltage max:
300V
Halogen free:
No
V0
UL-File No.:
E42024
Yes
Yes
Yes

NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Model:
Standard version
Number of branches:
0 N/A
Colour insulation:
Blue, Yellow, Red
Sleeve form:
Short
Suitable for solid cores:
Yes
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
For pull protected connections:
No
Voltage level:
Up to 600 V
Type of connection:
Other
Oil stop/centre bar:
No
Surface protection:
Tinned
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V0
Operating temperature:
-40-75 °C
Material:
Copper
Voltage max:
600V
Halogen free:
No
V0
UL-File No.:
E42024
Yes
Yes
Yes

Tab male disconnects A-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Model:
Plug
Max. current (Imax):
10-24 A
Insulation:
Partially isolated
Colour insulation:
Blue, Yellow, Red
With cam clamp:
No
With tap spreader:
No
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V0
Operating temperature:
-40-75 °C
Material:
Brass
Voltage max:
300V
Halogen free:
No
V0
UL-File No.:
E70188
Yes
Yes
Yes

Flaggkabelskor


NEMIQ
Model:
Bushing
Max. current (Imax):
10-15 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
No
Material insulation:
Other
Operating temperature:
-10-110 °C
Material:
Brass
Neck type:
Open barrel crimp
UL-File No.:
E70188
Yes
Yes

Fully Insulated female disconnects A-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Model:
Bushing
Max. current (Imax):
10-24 A
Insulation:
Fully isolated
Colour insulation:
Blue, Yellow, Red
With cam clamp:
No
With tap spreader:
No
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V0
Operating temperature:
-40-75 °C
Material:
Brass
Voltage max:
300V
Halogen free:
No
V0
UL-File No.:
E70188
Yes
Yes
Yes

Tab female disconnects A-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Model:
Bushing
Max. current (Imax):
8-24 A
Insulation:
Partially isolated
Colour insulation:
Blue, Yellow, Red
With cam clamp:
No
With tap spreader:
No
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V0
Operating temperature:
-40-75 °C
Material:
Brass
Voltage max:
300V
Halogen free:
No
V0
UL-File No.:
E70188
Yes
Yes
Yes

Piggyback disconnects A-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Model:
Bushing
Max. current (Imax):
10-15 A
Insulation:
Partially isolated
Colour insulation:
Blue, Red
With cam clamp:
No
With tap spreader:
Yes
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V0
Operating temperature:
-40-75 °C
Material:
Brass
Voltage max:
300V
Halogen free:
No
V0
UL-File No.:
E70188
Yes
Yes
Yes

Flatstift


NEMIQ
Model:
Plug
Max. current (Imax):
8-24 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
No
Material insulation:
Other
Operating temperature:
-10-110 °C
Material:
Brass
Neck type:
Open barrel crimp
Yes

Skarvhylsor


NEMIQ
Model:
UL model
Number of branches:
0 N/A
Insulation:
None
Colour insulation:
N/A
Sleeve form:
Short
Suitable for solid cores:
Yes
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
For pull protected connections:
No
Voltage level:
Up to 35 kV
Type of connection:
Other
Oil stop/centre bar:
No
Surface protection:
Tinned
Operating temperature:
110 °C
Material:
Copper
UL-File No.:
E44245
Yes
Yes
Yes

Flatstiftshylsor+hane


NEMIQ
Model:
Bushing
Max. current (Imax):
10-15 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
Yes
Material insulation:
Other
Operating temperature:
-10-110 °C
Material:
Brass
Neck type:
Open barrel crimp
UL-File No.:
E70188
Yes
Yes

Bladstiftskabelskor


NEMIQ
Reel/roll packaging:
No
Max. current (Imax):
19 A
Flange shape:
Flat-pin shape
According to DIN:
No
Insulation:
None
Colour insulation:
Other
Sleeve form:
Short
Suitable for solid cores:
Yes
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Operating temperature:
-55-110 °C
Material:
Copper
UL-File No.:
E42024
Yes
Yes

Pin terminals SP-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
19-48 A
Flange shape:
Pin shape
According to DIN:
No
Insulation:
Partially isolated
Colour insulation:
Blue, Yellow, Red
Sleeve form:
Long
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V0
Operating temperature:
-25-75 °C
Material:
Copper
Voltage max:
600V
Halogen free:
Yes
V0
UL-File No.:
E42024
Yes
Yes
Yes

NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
16-48 A
Flange shape:
Ring shape
According to DIN:
No
Insulation:
Partially isolated
Colour insulation:
Blue, Yellow, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V0
Operating temperature:
-40-75 °C
Material:
Copper
Voltage max:
600V
Halogen free:
No
V0
UL-File No.:
E42024
Yes
Yes
Yes

Hook terminals A-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
19-27 A
Flange shape:
Hook shape
According to DIN:
No
Insulation:
Partially isolated
Colour insulation:
Blue, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V0
Operating temperature:
-40-75 °C
Material:
Copper
Voltage max:
600V
Halogen free:
No
V0
UL-File No.:
E42024
Yes
Yes
Yes

Spade terminals A-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
16-48 A
Flange shape:
Fork shape
According to DIN:
No
Insulation:
Partially isolated
Colour insulation:
Blue, Yellow, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V0
Operating temperature:
-40-75 °C
Material:
Copper
Voltage max:
600V
Halogen free:
No
V0
UL-File No.:
E42024
Yes
Yes
Yes

Spade terminals SP-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
27 A
Flange shape:
Fork shape
According to DIN:
No
Insulation:
Partially isolated
Colour insulation:
Blue
Sleeve form:
Long
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V0
Operating temperature:
-40-75 °C
Material:
Copper
Voltage max:
600V
Halogen free:
No
V0
UL-File No.:
E42024
Yes
Yes
Yes

Spade terminals A-series with flanged spade


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
19-27 A
Flange shape:
Fork shape
According to DIN:
No
Insulation:
Partially isolated
Colour insulation:
Blue, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V0
Operating temperature:
-40-75 °C
Material:
Copper
Voltage max:
600V
Halogen free:
No
V0
UL-File No.:
E42024
Yes
Yes
Yes

Blade terminals A-series SF


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
19-48 A
Flange shape:
Flat-pin shape
According to DIN:
No
Insulation:
Partially isolated
Colour insulation:
Blue, Yellow, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V0
Operating temperature:
-40-75 °C
Material:
Copper
Voltage max:
600V
Halogen free:
No
V0
UL-File No.:
E42024
Yes
Yes
Yes

Blade terminals SP-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
19-48 A
Flange shape:
Flat-pin shape
According to DIN:
No
Insulation:
Partially isolated
Colour insulation:
Blue, Yellow, Red
Sleeve form:
Long
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V0
Operating temperature:
-40-75 °C
Material:
Copper
Voltage max:
600V
Halogen free:
No
V0
UL-File No.:
E42024
Yes
Yes
Yes
We are using Cookies to give you a superior user experience. If you want to find out more about cookies and how we use them, please go to our cookie page. Further browsing of this site indicates that you accept our cookie policy.