Refined by
Hide irrelevant options
Product Category
Surface protection
Bolt dimension metric (M..)
Cross section range
Max. current
With sight-hole
Trademark
Show all filters
Hide all filters
- Total: 11
KR - 0.75-6mm²
66675
Copper tube lugs for the Nordic market. For stranded wires.
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12D
n = nemiq // 35 = 35 mm² wire // 12 = M12 stud size // F = KRF
Inscriptions on the lugs neck can for ie be: 6
6 = Outside diameter of the neck (F).
When crimping with hexagon dies neck inscription and die markings must conform
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12D
n = nemiq // 35 = 35 mm² wire // 12 = M12 stud size // F = KRF
Inscriptions on the lugs neck can for ie be: 6
6 = Outside diameter of the neck (F).
When crimping with hexagon dies neck inscription and die markings must conform
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Suitable for Class 6 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 14-51 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 180° (horizontal)
- Series:
- KR/KS (0.75-6mm2)
KRF - 10-400mm²
00706
Copper tube lugs for the Nordic market. For stranded wires (class 5 and Class 6).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: F35-12
F = KRF // 35 = 35 mm² wire // 12 = M12 stud size.
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (F).
When crimping with hexagon dies neck inscription and die markings must conform.
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: F35-12
F = KRF // 35 = 35 mm² wire // 12 = M12 stud size.
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (F).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 5 conductor:
- Yes
- Suitable for Class 6 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 66-745 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 180° (horizontal)
- Series:
- KRF/KSF (10-500mm2)
KRF - 500-1000mm²
KRF_500-1000mm_vp
Copper tube lugs for the Nordic market. For stranded wires (class 5 and Class 6).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: F35-12
F = KRF // 35 = 35 mm² wire // 12 = M12 stud size.
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (F).
When crimping with hexagon dies neck inscription and die markings must conform.
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: F35-12
F = KRF // 35 = 35 mm² wire // 12 = M12 stud size.
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (F).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 5 conductor:
- Yes
- Suitable for Class 6 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 842-950 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 180° (horizontal)
- Series:
- KRF/KSF (500-1000mm2)
KRT - 10-400mm²
14701
Copper tube lugs for the Nordic market.
Copper tube lugs for stranded (class 5) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12T
n = nemiq // 35 = 35 mm² wire // 12 = M12 stud size // T = KRT
Inscriptions on the lugs neck can for ie be: 12
12 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
Copper tube lugs for stranded (class 5) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12T
n = nemiq // 35 = 35 mm² wire // 12 = M12 stud size // T = KRT
Inscriptions on the lugs neck can for ie be: 12
12 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 66-600 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 180° (horizontal)
- Series:
- KRT/KST(10-500mm2)
KRT 10-400mm² without inspection hole
Rörkabelskor - KRT UI_VP
Meets the measure requirements according to DIN 46235. Copper tube lugs for stranded (class 5 and class 6) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs neck can for ie be: 12
12 = Outside diameter of the neck (F).
When crimping with hexagon dies neck inscription and die markings must conform.
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs neck can for ie be: 12
12 = Outside diameter of the neck (F).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 66-288 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- No
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 180° (horizontal)
- Series:
- KRT/KST(10-500mm2)
KRDIN - 10-630mm² without inspection hole
Rörkabelsko_KRDIN_vp
Cable lugs according to DIN 46235. Suitable for multi-stranded conductors (class 2 and class 5).
Material: 99.9% pure Cu
Surface: > 4µ Sn
Marking on the flat of the tube cable lug can be, for example: n35-12DIN
n = Nemiq // 35 = 35 mm² cable // 12 = M12 hole // DIN = DIN46235
Marking is found on the neck of the cable lug as an indication of how they should be crimped.
Material: 99.9% pure Cu
Surface: > 4µ Sn
Marking on the flat of the tube cable lug can be, for example: n35-12DIN
n = Nemiq // 35 = 35 mm² cable // 12 = M12 hole // DIN = DIN46235
Marking is found on the neck of the cable lug as an indication of how they should be crimped.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Insulated:
- No
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- No
- Conductor category:
- Several
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 180° (horizontal)
KRD - 16-630mm²
14901
Copper tube lugs for stranded cable. (Class 2)
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12D
n = nemiq // 35 = 35 mm² wire // 12 = M12 stud size // D = KRD
Inscriptions on the lugs neck can for ie be: 11
11 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12D
n = nemiq // 35 = 35 mm² wire // 12 = M12 stud size // D = KRD
Inscriptions on the lugs neck can for ie be: 11
11 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 2 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 97-1027 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 180° (horizontal)
- Series:
- KRD/KSD(10-630mm2)
KR - UL-approved - 0.75-6mm²
66676
Meets the measure requirements according to DIN 46235. Copper tube lugs for stranded (class 5 and class 6) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: Cu 35-12
Cu = KRT UL // 35 = 35 wire // 12 = M12 stud size.
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: Cu 35-12
Cu = KRT UL // 35 = 35 wire // 12 = M12 stud size.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Insulated:
- No
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 180° (horizontal)
- Series:
- KR/KS (0.75-6mm2)
KRT - UL-approved - 10-500mm²
109101
Copper tube lugs for stranded and solid wires. Meets the measure requirements according to DIN 46235.
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: Cu 35-12
Cu = KRT UL // 35 = 35 mm² wire // 12 = M12 stud size.
When crimping with hexagon dies die number must correspond with the lugs neck diameter.
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: Cu 35-12
Cu = KRT UL // 35 = 35 mm² wire // 12 = M12 stud size.
When crimping with hexagon dies die number must correspond with the lugs neck diameter.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Insulated:
- No
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 180° (horizontal)
- Series:
- KRT/KST(10-500mm2)
KR/KRF - Nickel plated - 0.75-500mm²
66681
Copper tube lugs for the Nordic market. For stranded wires.
Material: 99.9% pure copper
Surface: > 5µ Ni
Inscriptions on the lugs palm can for ie be: n35-12F
n = Nemiq // 35 = 35 mm² wire // 12 = M12 stud size // F = KRF
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (F).
When crimping with hexagon dies neck inscription and die markings must conform.
Material: 99.9% pure copper
Surface: > 5µ Ni
Inscriptions on the lugs palm can for ie be: n35-12F
n = Nemiq // 35 = 35 mm² wire // 12 = M12 stud size // F = KRF
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (F).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Suitable for Class 6 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 40-842 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 340 °C
- Surface protection:
- Nickel-plated
- Material:
- Copper
- Connecting angle:
- 180° (horizontal)
- Series:
- KR/KS (0.75-6mm2), KRF/KSF (10-500mm2)
KRDIN- UL-approved - 2.5-120mm² without inspection hole
Rörkabelsko_KRDIN_utan_inspektionshål_vp
Meets the measure requirements according to DIN 46235. Copper tube lugs for stranded (class 5 and class 6) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Material: 99.9% pure copper
Surface: > 4µ Sn
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Insulated:
- No
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- No
- Conductor category:
- Several
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 180° (horizontal)
- Total: 11