0

Logged in as:

Show all filters

Hide all filters

Flaggkabelskor


NEMIQ
Model:
Bushing
Max. current (Imax):
10-15 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
No
Material insulation:
Other
Operating temperature:
-10-110 °C
Material:
Bronze, Brass
Neck type:
Open barrel crimp
Yes
Yes
Yes

Rundstiftshylsor


NEMIQ
Model:
Bushing
Max. current (Imax):
10 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
No
Material insulation:
Other
Operating temperature:
110 °C
Material:
Brass
Neck type:
Open barrel crimp
UL-File No.:
E78965
Yes
Yes

Flatstift (lödning)


NEMIQ
Model:
Plug
Max. current (Imax):
12-24 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
No
Material insulation:
Other
Operating temperature:
-40-110 °C
Material:
Brass

Flatstift (skruvmontage)


NEMIQ
Model:
Plug
Max. current (Imax):
12-24 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
No
Material insulation:
Other
Operating temperature:
-40-110 °C
Material:
Brass
Yes

Flatstift (skruvmontage)


NEMIQ
Model:
Plug
Max. current (Imax):
24 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
No
Material insulation:
Other
Operating temperature:
-40-110 °C
Material:
Brass
Yes

Flatstift (skruvmontage)


NEMIQ
Model:
Plug
Max. current (Imax):
12-24 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
No
Material insulation:
Other
Operating temperature:
-40-110 °C
Material:
Brass
Yes

Flatstift (skruvmontage)


NEMIQ
Model:
Plug
Max. current (Imax):
12-24 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
Yes
Material insulation:
Other
Operating temperature:
-40-110 °C
Material:
Brass
Yes
Yes

Flatstiftshylsor (öppningsbara)


NEMIQ
Model:
Bushing
Max. current (Imax):
10-24 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
No
Material insulation:
Other
Operating temperature:
-10-110 °C
Material:
Brass
Neck type:
Open barrel crimp
Yes

Battery teminals - BTSQ


NEMIQ NECORE
Type of accessory/spare part:
Battery terminal
Insulated:
No
Surface protection:
Tinned, Untreated
Cable connection type:
Klämning
Connection around pole:
Skruvförband
Accessory:
Yes
Spare part:
No

Battery teminals - BTLN


NEMIQ
Type of accessory/spare part:
Battery terminal
Insulated:
No
Surface protection:
Untreated
Cable connection type:
Skruv/Bult för Kabelsko
Connection around pole:
Skruvförband
Accessory:
Yes
Spare part:
No

Rundstift


NEMIQ
Model:
Plug
Max. current (Imax):
10 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
No
Material insulation:
Other
Operating temperature:
110 °C
Material:
Brass
Neck type:
Open barrel crimp
UL-File No.:
E78965
Yes
Yes

Japanese fuses - C series


NEMIQ
Explosion-proof:
No
Release characteristic:
Time-lag (T)
Optical defect indication:
Yes
Type of current:
DC
Colour code:
Blue
Nominal voltage DC:
32 V
Max. continuous voltage DC:
32 V
Max. current (Imax):
30-120 A
Nominal current:
30-120 A

Flaggkabelskor


NEMIQ
Model:
Bushing
Max. current (Imax):
15 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
No
Material insulation:
Other
Operating temperature:
-10-110 °C
Material:
Brass
Neck type:
Open barrel crimp
Yes

Toppskarvar, crimp


NEMIQ
Model:
Bushing
Max. current (Imax):
17 A
Insulation:
Fully isolated
Colour insulation:
Yellow
With cam clamp:
No
With tap spreader:
No
Colour:
Yellow
Material insulation:
Polyamide (PA)
Operating temperature:
-60-105 °C
Material:
Copper
Connector type:
Toppskarv, pressbar
Yes

Flatstift (skruvmontage) - B 2187 H4


NEMIQ
Model:
Plug
Max. current (Imax):
24 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
Yes
Material insulation:
Other
Operating temperature:
-40-110 °C
Material:
Brass
Yes

Flatstiftsförgreningar


NEMIQ
Model:
Bushing
Max. current (Imax):
24 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
Yes
Material insulation:
Other
Operating temperature:
-10-110 °C
Material:
Brass
Yes

Flatstiftsförgreningar


NEMIQ
Model:
Bushing
Max. current (Imax):
24 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
Yes
Material insulation:
Other
Operating temperature:
-10-110 °C
Material:
Brass
UL-File No.:
E44245
Yes
Yes

Flatstiftsförgreningar


NEMIQ
Model:
Bushing
Max. current (Imax):
24 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
Yes
Material insulation:
Other
Operating temperature:
-10-110 °C
Material:
Brass
Yes
Yes

Flatstiftsförgreningar


NEMIQ
Model:
Bushing
Max. current (Imax):
24 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
Yes
Material insulation:
Other
Operating temperature:
-10-110 °C
Material:
Brass
UL-File No.:
E44245
Yes
Yes

RKKB - Coil


NEMIQ
Number of cores:
2-16 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
60 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black, Grey, White
Operating temperature:
-25-70 °C
Core colour:
Several
Conductor surface:
Bare
Packaging:
Ring
Min. permitted bending radius, stationary application/permanent installation:
22-56 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

Sortimentlåda Isolerade kabelskor & HD 0560 – 1000 delar


NEMIQ
With transparent cover:
Yes
Housing material:
Plastic
Housing colour:
Black
Housing material quality:
Polyamide (PA)
Insulated cable end sleeves:
No
Insulated cable connections:
Yes
Non-insulated cable end sleeves:
No
Non-isolated cable connections:
Yes
Crimp cable lug for Cu-conductors:
Yes
Tube cable lug for Cu-conductors:
No
Cable screw glands:
No
With tool:
Yes
With cable tie:
No
Yes

Sortimentlåda Isolerade kabelskor & HD 0560 – 400 delar


NEMIQ
With transparent cover:
Yes
Housing material:
Plastic
Housing colour:
Black
Housing material quality:
Polyamide (PA)
Insulated cable end sleeves:
No
Insulated cable connections:
Yes
Non-insulated cable end sleeves:
No
Non-isolated cable connections:
Yes
Crimp cable lug for Cu-conductors:
Yes
Tube cable lug for Cu-conductors:
No
Cable screw glands:
No
With tool:
Yes
With cable tie:
No

Flatsäkring Micro


NEMIQ
Release characteristic:
Fast (F)
Type of current:
DC
Colour code:
Amber, Blue, Brown, Yellow, Grey, Green, Pink, Red, Purple, Other
Nominal voltage DC:
58 V
Max. current (Imax):
2-30 A
Nominal current:
2-30 A
Fuse type:
Micro
Yes

Butt splices AB-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Model:
Standard version
Number of branches:
0 N/A
Insulation:
Partially isolated
Colour insulation:
Blue, Yellow, Green, Red
Sleeve form:
Short
Suitable for solid cores:
Yes
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
For pull protected connections:
No
Voltage level:
Up to 600 V
Type of connection:
Other
Oil stop/centre bar:
No
Surface protection:
Tinned
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V0
Operating temperature:
-40-75 °C
Material:
Copper
Voltage max:
600V
Halogen free:
No
V0
UL-File No.:
E44245
Yes
Yes
Yes
We are using Cookies to give you a superior user experience. If you want to find out more about cookies and how we use them, please go to our cookie page. Further browsing of this site indicates that you accept our cookie policy.