Refined by
Hide irrelevant options
Bolt dimension metric (M..)
Cross section range
Max. current
Connecting Angle
With sight-hole
Show all filters
Hide all filters
- Total: 9
KR - Cable lugs angled -90º
KR bockad -90°_VP
Copper tube lugs for stranded (class 5 and class 6) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD, T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD, T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Suitable for Class 6 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 30-51 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 90°
- Series:
- KR/KS (0.75-6mm2)
KRF - Cable lugs angled -90º
KRF bockad -90°
"For stranded wires (class 5 and class 6).
Material: 99.9% pure copper
Surface: > 4µ Sn
Temperature range: Up to 200° C (392º F)
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD, T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform."
Material: 99.9% pure copper
Surface: > 4µ Sn
Temperature range: Up to 200° C (392º F)
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD, T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform."
- Suitable for Class 5 conductor:
- Yes
- Suitable for Class 6 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 66-842 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 90°
- Series:
- KRF/KSF (10-500mm2)
KRT - Cable lugs angled -90º
KRT bockad -90°
"Copper tube lugs for stranded (class 5) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12T
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // T = KRT, F = KRF, D= KRD
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform."
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12T
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // T = KRT, F = KRF, D= KRD
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform."
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 66-395 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 90°
- Series:
- KRT/KST(10-500mm2)
KRT - Cable lugs angled +45º
KRT bockad +45°_VP
Copper tube lugs for stranded (class 5) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12T
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // T = KRT, F = KRF, D= KRD
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12T
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // T = KRT, F = KRF, D= KRD
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 66-124 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 45°
- Series:
- KRT/KST(10-500mm2)
KRT - Cable lugs angled -45º
KRT bocka -45°_VP
Copper tube lugs for stranded (class 5) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12T
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // T = KRT, F = KRF, D = KRD
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12T
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // T = KRT, F = KRF, D = KRD
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 227-395 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 45°
- Series:
- KRT/KST(10-500mm2)
KRF - Cable lugs angled +45º
KRF bockad +45°_VP
For stranded wires. (class 5 and class 6)
Material: 99.9% pure copper
Surface: > 4µ Sn
Temperature range: Up to 200° C (392º F)
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD, T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
Material: 99.9% pure copper
Surface: > 4µ Sn
Temperature range: Up to 200° C (392º F)
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD, T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 5 conductor:
- Yes
- Suitable for Class 6 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 153-842 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 45°
- Series:
- KRF/KSF (10-500mm2)
KR - Cable lugs angled -45º
KR bocka -45°_VP
Copper tube lugs for stranded (class 5 and class 6) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD ,T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD ,T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Suitable for Class 6 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 51 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 45°
- Series:
- KR/KS (0.75-6mm2)
KRDIN - Cable lugs angled +45º
Rörkabelsko_bockad_45_KRDIN_vp
Cable lugs according to DIN 46235. Suitable for multi-stranded conductors (class 2 and class 5).
Material: 99.9% pure Cu
Surface: > 4µ Sn
Marking on the flat of the tube cable lug can be, for example: n35-12DIN
n = Nemiq // 35 = 35 mm² cable // 12 = M12 hole // DIN = DIN46235
Marking is found on the neck of the cable lug as an indication of how they should be crimped.
Material: 99.9% pure Cu
Surface: > 4µ Sn
Marking on the flat of the tube cable lug can be, for example: n35-12DIN
n = Nemiq // 35 = 35 mm² cable // 12 = M12 hole // DIN = DIN46235
Marking is found on the neck of the cable lug as an indication of how they should be crimped.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Insulated:
- No
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- No
- Conductor category:
- Several
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 180° (horizontal)
KRF - Cable lugs angled -45º
KRF bockad -45°_VP
For stranded wires (class 5 and class 6).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD, T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD, T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 5 conductor:
- Yes
- Suitable for Class 6 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 97-842 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 45°
- Series:
- KRF/KSF (10-500mm2)
- Total: 9