0

Logged in as:

Show all filters

Hide all filters

  • Total: 14

RADOX 125 - Conipack


Huber+Suhner
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Grey, Black, White, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-55-145 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
125 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Grey, Yellow, Brown, White, Blue
Material insulation:
Polyolefin (POE)
Core colour:
Blue, Brown, Green/yellow, Black, White
Conductor surface:
Tinned
Halogen free:
Yes
Packaging:
CK
Min. permitted bending radius, stationary application/permanent installation:
6.75 mm
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RADOX 155 - Spools


Huber+Suhner
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
Flame retardant:
No
Permitted cable outer temperature after assembling without vibration:
-55-155 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
155 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Purple
Material insulation:
Polyolefin (POE)
Operating temperature:
-55-155 °C
Core colour:
Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Red, Black, White
Conductor surface:
Tinned
Halogen free:
No
Packaging:
Spool HS150, Spool HS151, Spool HS400, Spool HS200, Spool HS600
Min. permitted bending radius, stationary application/permanent installation:
4.35-37.2 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

RADOX 155 - Industribobin


Huber+Suhner
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Grey, Red, Black, White, Other
Flame retardant:
No
Permitted cable outer temperature after assembling without vibration:
-55-155 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
155 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Black, Grey, Green/yellow, Red, White, Blue
Material insulation:
Polyolefin (POE)
Operating temperature:
-55-155 °C
Core colour:
Blue, Grey, Green/yellow, Red, Black, White
Conductor surface:
Tinned
Halogen free:
No
Packaging:
Spool HS400, Spool HS200
Min. permitted bending radius, stationary application/permanent installation:
4.35-10.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

RADOX 155 - Conipack


Huber+Suhner
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Black
Flame retardant:
No
Conductor material:
Copper
Twisted cores:
No
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Black, Brown, Blue
Material insulation:
Polyolefin (POE)
Core colour:
Blue, Brown, Black
Conductor surface:
Tinned
Halogen free:
No
Packaging:
CK
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RADOX 125 - Spool


Huber+Suhner
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-55-145 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
125 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Purple
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-125 °C
Core colour:
Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Red, Black, White
Conductor surface:
Tinned
Halogen free:
Yes
Packaging:
Spool HS150, Spool HS151, Spool HS200
Min. permitted bending radius, stationary application/permanent installation:
4.35-20.25 mm
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RADOX 125 - Industry Spool


Huber+Suhner
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-55-145 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
125 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-125 °C
Core colour:
Blue, Brown, Yellow, Grey, Green, Green/yellow, Orange, Red, Black, White
Conductor surface:
Tinned
Halogen free:
Yes
Packaging:
Spool HS150, Spool HS400, Spool HS200
Min. permitted bending radius, stationary application/permanent installation:
4.5-10.05 mm
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RADOX 125 - Drum


Huber+Suhner
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red, Black, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-55-145 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
125 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Green/yellow, Red
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-125 °C
Core colour:
Green/yellow, Red, Black
Conductor surface:
Tinned
Halogen free:
Yes
Packaging:
Drum
Min. permitted bending radius, stationary application/permanent installation:
25.5-73.5 mm
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Availability:
No

Huber+Suhner
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Black
Flame retardant:
No
Permitted cable outer temperature after assembling without vibration:
-55-155 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
155 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
No
Conductor category:
Class 5 = flexible
Core colour:
Black
Conductor surface:
Tinned
Min. permitted bending radius, stationary application/permanent installation:
4.35 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Availability:
Yes

Huber+Suhner
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Conductor material:
Copper
Twisted cores:
No
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Core colour:
Green/yellow
Conductor surface:
Tinned
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Availability:
No

Huber+Suhner
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red
Flame retardant:
According to IEC/EN 60332-1-2
Conductor material:
Copper
Twisted cores:
No
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Core colour:
Red
Conductor surface:
Tinned
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Availability:
Yes

Huber+Suhner
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Grey
Permitted cable outer temperature after assembling without vibration:
-55-145 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
125 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Drain wire:
No
Conductor category:
Class 5 = flexible
Core colour:
Grey
Conductor surface:
Tinned
Min. permitted bending radius, stationary application/permanent installation:
6.75 mm
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Availability:
No

Huber+Suhner
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Black
Permitted cable outer temperature after assembling without vibration:
-55-145 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
125 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Drain wire:
No
Conductor category:
Class 5 = flexible
Core colour:
Black
Conductor surface:
Tinned
Min. permitted bending radius, stationary application/permanent installation:
4.35 mm
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Availability:
No

Huber+Suhner
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red
Conductor material:
Copper
Twisted cores:
No
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Drain wire:
No
Conductor category:
Class 5 = flexible
Core colour:
Red
Conductor surface:
Tinned
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Availability:
No

Huber+Suhner