0

Logged in as:

Show all filters

Hide all filters

  • Total: 4

DINFLEX-CY (LiYCY) - Spool 100m


NEMIQ
Number of cores:
2-50 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
Yes
Max. conductor temperature:
70 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Braiding
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Grey
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-30-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
18.5-64.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

DINFLEX-CY (LiYCY) - Korta längder


NEMIQ
Number of cores:
2-50 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
Yes
Max. conductor temperature:
70 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Braiding
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Black, Grey
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-30-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
Yes, No
Min. permitted bending radius, stationary application/permanent installation:
18.5-76.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

DINFLEX-CY (LiYCY)


NEMIQ
Number of cores:
2-50 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
Yes
Max. conductor temperature:
70 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Braiding
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Grey
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-30-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
18.5-64 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Availability:
Yes

Number of cores:
40 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
Yes
Max. conductor temperature:
70 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Braiding
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Grey
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-30-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
56.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
  • Total: 4