0

Logged in as:

Show all filters

Hide all filters

RQ (H05Z-K, H07Z-K) - Drum


NEMIQ
Number of cores:
1 .
Material core insulation:
Other
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-15-90 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
90 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black
Material insulation:
Polymen
Operating temperature:
-5-90 °C
Core colour:
Black
Conductor surface:
Bare
Halogen free:
Yes
Packaging:
Drum
Min. permitted bending radius, stationary application/permanent installation:
36.76-63.44 mm
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

KRF - 2 stud holes, 10-50 mm²


NEMIQ
Suitable for Class 5 conductor:
Yes
Suitable for Class 6 conductor:
Yes
Insulated:
No
Max. current (Imax):
66-842 A
Number of mounting holes:
2 .
Flange shape:
Ring shape
Colour insulation:
Other
Slender flange model:
No
With sight-hole:
Yes
Conductor category:
Several
Max Temp:
150 °C
Surface protection:
Tinned
Material:
Copper
Connecting angle:
180° (horizontal)
Series:
KRF/KSF (10-500mm2)
Yes
Yes

PCG BASIC, Standard cable gland in consumer pack


NEMIQ
Pressure-compensating:
No
Degree of protection (IP):
IP68
With strain relief:
Yes
Model:
Straight
Material quality:
Polyamide (PA)
RAL-number:
7035 .
Thread type:
Metric
Glass-fibre reinforced:
No
Shock resistant:
Yes
Bend radius protection/trumpet flare:
No
With locknut:
Yes
Snapping in opening:
Yes
Multi seal area:
No
Flat cable coupling:
No
Explosion-tested version:
No
For armoured cable:
No
EMC-version:
No
Screened:
No
Type of sealing:
Sealing ring
For Ex-zone gas:
None
For Ex-Zone dust:
None
Colour:
Grey
Surface protection:
Untreated
Operating temperature:
-40-100 °C
Material:
Plastic
Halogen free:
Yes
Wrench width:
19-33 mm
Yes

Assortment box Continental and Glass fuses - 73pcs

Installation Kit – Solar Panel Connectors


NEMIQ
With locking device (for mechanical tools):
Yes
Inserts exchangeable:
Yes
Number of included inserts:
1-2 .
With automatic return:
Yes
Cycle time:
2 s
Suitable for:
Cable lugs and connectors
Construction/operation:
Ratchet model mechanical
Compression shape:
Square compression, Roll compression (shrinking), Universal (exchangeable inserts)

Plastbuntband med metallinnehåll - DCT-serien


NEMIQ
Detectable:
Yes
Min. tensile strength:
80-540 N
Model:
Internal toothing
Material quality:
Polyamide (PA)
Band closure:
Plastic lip/-cam
Transparent:
No
Fluorescent:
No
Solvable fastener:
No
Text strip:
None
Type of fastening:
None
Colour:
Blue
Surface protection:
Untreated
Material:
Plastic with metal pigments
Max. tensile force:
80-540 N
Inflammability class of insulation material according to with UL94:
Other
MIL approval:
No
VG approval:
No
UL approval:
No
Approved according to CE:
No
With approval according to UL:
No
Approved according to DNV:
No

NHSA, 3:1, with adhesive, reel


NEMIQ
Model:
Thin-walled
Transparent:
No
Type:
Heat-shrink
Shrink rate:
3:1
With inner glue:
No
Printable:
No
Colour:
Red
Material:
Polyolefin (PO-X)
Halogen free:
No
Yes
UL approval:
No

NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Max. current (Imax):
19-27 A
Flange shape:
Fork shape
According to DIN:
No
Insulation:
Partially isolated
Colour insulation:
Blue, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material insulation:
Polycarbonate (PC)
Fire classification:
According to UL94V2
Operating temperature:
-40-125 °C
Material:
Copper
Voltage max:
600V
V2
UL-File No.:
E44245
Yes
Yes

Lighting connector, with lever


NEMIQ
Nominal voltage:
600 V
Nominal current:
32 A
Transparent:
No
Number of clamp positions:
4-10 .
With operation lever:
Yes
Suitable for solid core:
Yes
Suitable for flexible core:
Yes
Suitable for multi-wire core:
Yes
Colour:
Multi-coloured
Operating temperature:
-40-105 °C
V2

Crimping tool - NMC mini


NEMIQ
Number of crimps:
1
With locking device (for mechanical tools):
Yes
Inserts exchangeable:
No
Number of included inserts:
1 .
With automatic return:
Yes
Cycle time:
2 s
Suitable for:
Cable end sleeves, Cable lugs and connectors
Construction/operation:
Mechanical
Compression shape:
Trapezoid compression, Arbour clamping, Oval pressing, Roll compression (shrinking)

Crimp tool NAE 00816 SQ


NEMIQ
Number of crimps:
1
With locking device (for mechanical tools):
Yes
Inserts exchangeable:
Yes
Number of included inserts:
1 .
With automatic return:
Yes
Suitable for:
Cable end sleeves
Construction/operation:
Mechanical
For component:
End sleeves
Compression shape:
Square compression
Availability:
No

NEMIQ
Insulated:
No
Max. current (Imax):
334 A
Number of mounting holes:
1 .
Flange shape:
Ring shape
Colour insulation:
Other
Slender flange model:
No
With sight-hole:
Yes
Conductor category:
Several
Max Temp:
150 °C
Surface protection:
Tinned
Material:
Copper
Connecting angle:
90°
Series:
KRF/KSF (10-500mm2)
Yes
Yes

Bolt-on


NEMIQ
Explosion-proof:
No
Release characteristic:
Time-lag (T)
Optical defect indication:
No
Type of current:
DC
Colour code:
Blue, Brown, Yellow, Grey, Green, Pink, Red, Other, Orange, White
Nominal voltage DC:
70 V
Max. continuous voltage DC:
70 V
Nominal current:
80-500 A

RK Drum


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Grey, Red, Black, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Grey, Green/yellow, Red
Material insulation:
Polyvinyl chloride (PVC)
Designations:
H07V-K (RK 1.5 - 400mm2)
Operating temperature:
-5-70 °C
Core colour:
Grey, Green/yellow, Red, Black
Conductor surface:
Bare
Halogen free:
No
Packaging:
Drum
Min. permitted bending radius, stationary application/permanent installation:
25.6-60.8 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RK (H05V-K, H07V-K)


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
300-600 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Pink, Purple, Light blue, Dark blue
Material insulation:
Polyvinyl chloride (PVC)
Designations:
H05V-K (RK 0.5-1.0mm2), H07V-K (RK 1.5 - 400mm2)
Operating temperature:
-5-70 °C
Core colour:
Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Pink, Red, Black, White
Conductor surface:
Bare
Halogen free:
No
Packaging:
Ring, Carton (box)
Min. permitted bending radius, stationary application/permanent installation:
12.4-18.8 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RK (H05V-K, H07V-K)


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Grey, Red, Black, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Grey, Green/yellow, Red, Light blue, Dark blue
Material insulation:
Polyvinyl chloride (PVC)
Designations:
H07V-K (RK 1.5 - 400mm2)
Operating temperature:
-5-70 °C
Core colour:
Blue, Grey, Green/yellow, Red, Black
Conductor surface:
Bare
Halogen free:
No
Packaging:
Ring
Min. permitted bending radius, stationary application/permanent installation:
25.6-60.8 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

ST2, släta stålbuntband med låskula - SS316


NEMIQ
Detectable:
No
Min. tensile strength:
667-1335 N
Model:
Without toothing
Material quality:
Stainless steel 316 (V4A)
Operating temperature:
-80-538 °C
Mounting temperature:
-80-538 °C
Band closure:
Ball latch
UV-stable acc. ASTM D6779:
Yes
Transparent:
No
Fluorescent:
No
Solvable fastener:
No
Text strip:
None
Type of fastening:
None
Colour:
Stainless steel
Surface protection:
Untreated
Material:
Metal
Halogen free:
Yes
Max. tensile force:
667-1335 N
Inflammability class of insulation material according to with UL94:
Other
MIL approval:
No
VG approval:
No
Yes

ST2, släta stålbuntband med låskula, med beläggning


NEMIQ
Detectable:
No
Min. tensile strength:
465-1200 N
Model:
Without toothing
Material quality:
Stainless steel 316 (V4A)
Operating temperature:
-80-150 °C
Mounting temperature:
-80-150 °C
Band closure:
Ball latch
UV-stable acc. ASTM D6779:
No
Transparent:
No
Fluorescent:
No
Solvable fastener:
No
Text strip:
None
Type of fastening:
None
Colour:
Black
Surface protection:
Plastic-coated
Material:
Metal
Halogen free:
Yes
Max. tensile force:
465-1200 N
Inflammability class of insulation material according to with UL94:
Other
MIL approval:
No
VG approval:
No
Yes

Svetskabel - Dubbelisolerad, bobin


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Orange, Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-45-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
80 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black, Orange, Red
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-40-80 °C
Core colour:
Orange, Red, Black
Conductor surface:
Bare
Halogen free:
No
Packaging:
Reel B5
Min. permitted bending radius, stationary application/permanent installation:
43.2-90 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Availability:
No

NEMIQ
Fire resistance according to UL94:
HB
Oil resistant:
Yes
Lengthwise slotted:
Yes
Closable (two-part):
No
With draw wire:
No
High conducting inner coating:
No
Colour:
Black
Operating temperature:
-40-120 °C
Material:
Polyamide 6
Halogen free:
Yes
Suitable in fire resistance areas:
Yes
Approved according to DIN EN 61386-23:
No
Approved according to UR:
No
Approves according to Vd TÜV/GGVS:
No
Approved according to LUL/British Standard:
No
Approved according to Lloyd's Register TA:
No
Approved according to UTAC:
No
Approved according to DIN 5510:
No
Approved according to NF F 16-101:
No
Approved according to CSA:
No

Tab female disconnects NA-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Model:
Bushing
Max. current (Imax):
10-15 A
Insulation:
Partially isolated
Colour insulation:
Blue, Red
With cam clamp:
No
With tap spreader:
No
Material insulation:
Polyamide (PA)
Fire classification:
According to UL94V2
Operating temperature:
-40-105 °C
Material:
Brass
Voltage max:
300V
Halogen free:
Yes
V2
UL-File No.:
E78965, E44245
Yes
Yes

RDOE (H07RN-F) - Drum


NEMIQ
Number of cores:
2-7 .
Material core insulation:
Rubber
Specification core insulation:
Rubber - ethylene propylene rubber (EPR)
Core identification:
Colour
Protective conductor:
Yes
Material outer sheath:
Rubber
Specification material outer sheath:
Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-60 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
60 °C
Screen:
No
Armouring/reinforcement:
None
Drain wire:
No
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Core colour:
Several
Conductor surface:
Bare
Min. permitted bending radius, stationary application/permanent installation:
55-87.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

H01N2-D FT - Drum


NEMIQ
Number of cores:
1 .
Material core insulation:
Rubber
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-20-80 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
80 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Single insulated
Core colour:
Red, Black
Conductor surface:
Tinned
Min. permitted bending radius, stationary application/permanent installation:
66-115.2 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RDOE (H07RN-F) - Drum 500 m


NEMIQ
Number of cores:
3-7 .
Material core insulation:
Rubber
Specification core insulation:
Rubber - ethylene propylene rubber (EPR)
Core identification:
Colour
Protective conductor:
Yes
Material outer sheath:
Rubber
Specification material outer sheath:
Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-60 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
60 °C
Screen:
No
Armouring/reinforcement:
None
Drain wire:
No
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Core colour:
Several
Conductor surface:
Bare
Min. permitted bending radius, stationary application/permanent installation:
59.5-87.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes