Refined by
Hide irrelevant options
Produktgrupp
Show all filters
Hide all filters
Fuse holder
För Mega L-säkringar med lock.
Säkringen skruvas fast med 2 stycken M8 muttrar. Hållaren fästs med 2 bultar.
Maximal kabeldiameter: 25 mm OBS! Säkring ingår ej.
- Connection type:
- Screw connection
- Rated current:
- 500 A
- Rated voltage:
- 32 V
- Type of current:
- DC
- Mounting method:
- Housing mounting
Fuse holder
För 2 stycken Mega L-säkringar med lock.
Säkringen skruvas fast med 2 stycken M8 muttrar. Hållaren fästs med 4 bultar.
Maximal kabeldiameter: 25 mm OBS! Säkring ingår ej.
- Connection type:
- Screw connection
- Rated current:
- 500 A
- Rated voltage:
- 32 V
- Type of current:
- DC
- Mounting method:
- Housing mounting
- Connection type:
- Other
- Rated current:
- 40 A
- Rated voltage:
- 58 V
- Type of current:
- DC
- Mounting method:
- Other
KRD - 2-hål - 10-500mm²
Rörkabelskor 2-håls, KRD. För fåtrådig kabel (klass 2).
Material: 99.9% ren Cu
Ytbehandling: > 4µ Sn
Märkning på rörkabelskons platta kan t.ex. vara: n35-12D
n = Nemiq // 35 = 35 mm² kabel // 12 = M12 hål // D = KRD // F = KRF // T = KRT
Märkning på rörkabelskons hals kan t.ex. vara: 13
13 = Ytterdiameter på halsen (OD-måttet).
Vid pressning med 6-kantsbackar skall halsmärkning och backmärkning överensstämma.
- Suitable for Class 2 conductor:
- Yes
- Max. current (Imax):
- 1027 A
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
KR - Cable lugs angled -90º
Copper tube lugs for stranded (class 5 and class 6) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD, T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Suitable for Class 6 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 30-51 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 90°
- Series:
- KR/KS (0.75-6mm2)
KRT - Cable lugs angled +45º
Copper tube lugs for stranded (class 5) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12T
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // T = KRT, F = KRF, D= KRD
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 66-124 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 45°
- Series:
- KRT/KST(10-500mm2)
KR - Cable lugs angled -45º
Copper tube lugs for stranded (class 5 and class 6) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD ,T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Suitable for Class 6 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 51 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 45°
- Series:
- KR/KS (0.75-6mm2)
KRT - Cable lugs angled -45º
Copper tube lugs for stranded (class 5) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12T
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // T = KRT, F = KRF, D = KRD
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 227-395 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 45°
- Series:
- KRT/KST(10-500mm2)
KRF - Cable lugs angled -45º
For stranded wires (class 5 and class 6).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD, T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 5 conductor:
- Yes
- Suitable for Class 6 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 97-842 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 45°
- Series:
- KRF/KSF (10-500mm2)
Kopplingskabel för solceller H1Z2Z2-K - Trumma
H1Z272-K solar cell connection cable offers an optimal solution when it comes to connecting solar panels to each other or with junction boxes and frequency converters. The cable is very resistant to mechanical impact. Good properties in terms of temperature range, chemical resistance, UV resistance and short-circuit resistance. The cable is halogen free.
Construction:
Conductor: Tinned copper according to IEC 60228 class 5
Conductor insulation:
Inner sheath: POLYOLEFIN
Outer sheath: POLYOLEFIN
Coat color: See product facts
Technical data:
Minimum bending radius:
Variable = D < 8 mm² x cable diameter Ø
Fixed = D > 8 mm3 x cable diameter Ø
Temperature range: -40ºC to + 110ºC
Rated voltage: Uo / U AC: 1000V, DC: 1500V
Test voltage: 6500VAC
Approvals:
EN 50575: 2014
EN 50575 / A1: 2016 CE EN 50618 CPR Eca
R3IB - Single conductor
Flame retardant thermoplastic cable, suitable for vehicles
use on low voltage applications and systems, even in hot environments, without direct contact of heat sources on the cable. Heat-resistant cable, suitable for applications inside the engine compartment.
Packaging (OD x Hub x Width):
Spool B6: 250mm x 56mm x 95mm
Construction:
Conductor: Annealed multi-wire copper class 3
Leader insulation: XHFFR
Coat color: See product data
Technical data:
100V
Temp. range: -40ºC to + 125ºC
Approvals:
ISO 6722 class C
R3IB - Multi conductor
Flame retardant thermoplastic cable, suitable for vehicles
use on low voltage applications and systems, even in hot environments,
without direct contact of heat sources on the cable. Heat-resistant cable, suitable for applications inside the engine compartment.
Packaging (OD x Hub x Width):
Spool B6: 250mm x 56mm x 95mm
Construction:
Conductor: Annealed multi-wire copper class 3
Leader insulation: XHFFR
Sheath color: Black
Conductor color: See product data
Technical data:
100V
Temp. range: -40ºC to + 125ºC
Approvals:
ISO 6722 class C
- Thread type inner thread:
- Metric, PG
- Thread type outer thread:
- Metric, PG
- Nickel-plated:
- Yes
- Explosion-proof:
- No
- Material quality:
- Other
- Material:
- Brass
- Thread type inner thread:
- PG
- Thread type outer thread:
- Metric
- Nickel-plated:
- No
- Explosion-proof:
- No
- Material quality:
- Polyamide (PA)
- Material:
- Plastic
- Thread type inner thread:
- Metric
- Thread type outer thread:
- PG
- Nickel-plated:
- No
- Explosion-proof:
- No
- Material quality:
- Polyamide (PA)
- Material:
- Plastic
- Thread type inner thread:
- Metric
- Thread type outer thread:
- Metric
- Nickel-plated:
- No
- Explosion-proof:
- No
- Material quality:
- Polyamide (PA)
- Material:
- Plastic
- Thread type inner thread:
- Metric, PG
- Thread type outer thread:
- Metric, PG
- Nickel-plated:
- Yes
- Explosion-proof:
- No
- Material quality:
- Other
- Material:
- Brass
Förstoring plast, metrisk
Material: Polyamid 6 Drifttemperatur: -25 grader C till +100 grader C Färg:Grå RAL 7035
- Thread type inner thread:
- Metric
- Thread type outer thread:
- Metric
- Nickel-plated:
- No
- Explosion-proof:
- No
- Material quality:
- Polyamide (PA)
- Material:
- Plastic
- Thread type inner thread:
- PG
- Thread type outer thread:
- NPT
- Thread size outer thread (inch):
- 3/4 inch, 1 1/2 inch, 2 inch
- Nickel-plated:
- Yes
- Explosion-proof:
- No
- Material quality:
- Other
- Material:
- Brass
- Thread type inner thread:
- Metric
- Thread type outer thread:
- PG
- Nickel-plated:
- Yes
- Explosion-proof:
- No
- Material quality:
- Other
- Material:
- Brass
- Thread type inner thread:
- PG
- Thread type outer thread:
- Metric
- Nickel-plated:
- Yes
- Explosion-proof:
- No
- Material quality:
- Other
- Material:
- Brass
RKKB - Spool
Round flexible cable for car and boat applications.
Packaging (OD x Hub x Width):
Spool B3: 160mm x 56mm x 50mm
Spool B4: 160mm x 56mm x 90mm
Spool B5: 200mm x 56mm x 88mm
Drum
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Identification line up on conductors: Grey, black, red, blue, yellow, green, brown, white, purple, pink
Outer Sheath: PVC
Sheath identification: Grey, black, white
Technical data:
Rating voltage: 60V
Temperature range: -25ºC to +70ºC (-13ºF to +158ºF)
- Number of cores:
- 2-17 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 60 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black, Grey, White
- Core colour:
- Several
- Conductor surface:
- Bare
- Packaging:
- Reel B3, Reel B4, Reel B5
- Min. permitted bending radius, stationary application/permanent installation:
- 18.4-61.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RKXB - Spool
Flat flexible connection cable for car and boat applications.
Packaging (OD x Hub x Width):
Spool B3: 160mm x 56mm x 50mm
Spool B4: 160mm x 56mm x 90mm
Spool B5: 200mm x 56mm x 88mm
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Core color (unless otherwise specified): Gray, black
Outer Sheath: PVC
Sheath Colour: Grey, black
Technical data:
Rating voltage: 60V
Temperature range: -25ºC to +70ºC (-13ºF to +158ºF)
- Number of cores:
- 2-3 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 60 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black, Grey
- Core colour:
- Several
- Conductor surface:
- Bare
- Packaging:
- Ring, Reel B3, Reel B4, Reel B5
- Min. permitted bending radius, stationary application/permanent installation:
- 20.8-37.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
MKKB
Cable used mainly in motor vehicles as ignition cable. It is built of a multi-wire standard copper conductor and insulation and sheath of standard PVC that can withstand temperature range -25 -C to + 70ºC.
Packaging (YD x Hub x Width)
Bobin B3: 160mm x 56mm x 50mm
Max voltage: 15kV
Outer diameter: 5.2mm
Structure
Conductor: Stranded copper
Outer sheath: PVC, double insulated
Coat color: Black or Red
- Number of cores:
- 1 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red, Black
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 60 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black, Red
- Core colour:
- Red, Black
- Conductor surface:
- Bare
- Packaging:
- Reel B3
- Min. permitted bending radius, stationary application/permanent installation:
- 21 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No